This document provides information about initializing, discovering, defining, and managing the PowerLinux (IBM Power 7R1/7R2/7R4 and IBM Power 8 S Class servers) hardware. If not expressly stated, everything described in this document is supported in xCAT 2.7 and above.
Currently, xCAT support 3 kind of hardware arch to manage the PowerLinux machine, they are ppc64(RH and sles), x86_64(RH and sles) and ppc64le(RH7.1).
The following terms will be used in this document:
xCAT DFM: Direct FSP Management is the name that we use to describe the ability for xCAT software to communicate directly to the System p server's service processor without the use of the HMC for management.
CEC node: A node with attribute hwtype set to cec which represents a System P CEC (i.e. one physical server).
FSP node: FSP node is a node with the hwtype set to fsp and represents one port on the FSP. Each FSP has two ports, so there can be two FSP nodes defined by xCAT per CEC. System admins will always use the CEC node for the hardware control commands. xCAT will automatically use the four FSP node definitions and their attributes for hardware connections.
Service LAN: The network that connects the xCAT mgmt node (and service nodes if you have them) to the FSPs to control the nodes out of band.
Management LAN: The network that connects the xCAT mgmt node (and service nodes if you have them) to the in-band NIC of the nodes to deploy the OS and do other mgmt operations to the nodes.
Most of the operations mentioned in this document, are done through DFM, not using the HMC. This requires the xCAT Direct FSP Management plugin (xCAT-dfm-..rpm), which is not part of the core xCAT open source, but is available as a free download from IBM. You must download this and install it on your xCAT management node (and possibly on your service nodes, depending on your configuration) before proceeding with this document.
Download DFM and the prerequisite hardware server package from Fix Central :
Product Group: Cluster Software
Product: direct FSP management plug-in for xCAT
[RH7.1 ppc64le]:
* DFM-2.9.1.7-powerLE-Linux
[ubuntu14.04.x ppc64le:]
* DFM-2.9.1.7-powerLE-Linux-ubuntu
[RH on ppc64]:
* DFM-2.8.3.71-power-Linux
[RH on x86_64]:
* DFM-2.8.3.71-x86_64-Linux
Product Group: Cluster Software
Product: IBM High Performance Computing (HPC) Hardware Server
[RH7.1 ppc64le]:
* HARDWARESVR-1.2.0.0-powerLE-Linux
[ubuntu14.04.x ppc64le]:
* HARDWARESVR-1.2.0.0-powerLE-Linux-ubuntu
[RH on ppc64]:
* HARDWARESVR-1.2.0.0-power-Linux
[RH on x86_64]:
* HARDWARESVR-1.2.0.0-x86_64-Linux-RHEL6
The downloaded packages contain the installable rpm/deb which has been tar-ed and zipped(compressed). After downloading these packages, uncompress, untar and install the hardware server package first and then do the same for the DFM package:
[For RH]:
If you followed the xCAT documentation to install xCAT on the mgmt node, you should already have the yum repositories set up to pull in whatever xCAT dependencies and distro RPMs are needed (libstdc++, libgcc, openssl, etc.).
yum install xCAT-dfm-*.rpm ISNM-hdwr_svr-*.rpm
Use the following command to install dfm and hdwr_svr:
dpkg -i xcat-dfm-*.ppc64el.deb isnm-hdwr-svr-*.ppc64el.deb
When setting up a new cluster, you can use the xCAT command lsslp to create the proper definition of all of the cluster hardware in the xCAT database, by automatically discovering and defining them. This is optional - you can define all of the hardware in the database by hand, but that can be confusing, time consuming, and error prone.
Note: this document focuses on the following environment:
The hardware discovery should be performed after the Management Node is installed and configured with xCAT as indicated by this flow:
Note: the firewall should be disabled on the mgmt node, otherwise the command lsslp will return no responses and can't discover nodes.
Here is the summary of the steps needed to discover the hardware and define it properly in the database. Each step of the summary is explained in more detail in the subsequent sections.
Each step is explained in more detail below.
In the examples given below, it is assumed that the xCAT management node has 2 NICs, one is connected to service lan 10.0.0.0/255.255.255.0, another is connected to service lan 192.168.0.0/255.255.255.0.
xCAT uses SLP to discover the hardware components on the service networks. Before doing this, you must validate the following:
The power linux cluster may be using the Juniper ethernet switch to support the FSP HW service VLANS. The information below was on how to enable Juniper switch working with igmp-snooping for SLP support. We recommend to remove the HW service vlans from igmp-snooping protocol settings. The default configuration for igmp-snooping on the IBM J48E switch is to enable igmp-snooping for all VLANs:
protocols {
igmp-snooping {
vlan all;
The Juniper administrator commands to make this change are the following after entering into edit mode:
{master:0}[edit]
admin@j48052# edit protocols igmp-snooping
{master:0}[edit protocols igmp-snooping]
admin@j48052# show vlan all;
{master:0}[edit protocols igmp-snooping]
admin@j48052# set vlan management
{master:0}[edit protocols igmp-snooping]
admin@j48052# delete vlan all
{master:0}[edit protocols igmp-snooping]
admin@j48052# show vlan management;
{master:0}[edit protocols igmp-snooping]
admin@j48052# commit check
if clean, then
{master:0}[edit protocols igmp-snooping]
admin@j48052# commit synchronize
Note:use the 'synchronize' if more than one switch configured in virtual chassis
This section provides the commands used to set up the xCAT HW service VLANs in the the xCAT database and dhcp server environment.
Note: if you are adding new additional hardware to an existing cluster (not initially creating the cluster) then you can skip this section. If you are adding new networks to the cluster, then you will need to execute some steps in this section.
If you haven't already, configure with static IP addresses the management node's NICs that are connected to the service VLAN and cluster management VLAN.
If you already had the management node's service LAN NICs configured when you installed xcat, it automatically ran "makenetworks" and created the necessary entries in the networks table. If not, run:
makenetworks
Now set the networks.dynamicrange attribute for each service LAN. For example the following represents 2 HW VLANS:
chdef -t network 10_0_0_0-255_255_255_0 dynamicrange=10.0.0.20-10.0.0.200
chdef -t network 192_168_0_0-255_255_255_0 dynamicrange=192.168.0.20-192.168.0.200
If you want the network definitions to have more user friendly names in the database, you can set them to anything you want. For example:
chdef -t network 10_230_0_0-255_255_0_0 -n servicelan1
chdef -t network 10_231_0_0-255_255_0_0 -n servicelan2
Set site.dhcpinterfaces to the list of NICs (on the management node and service nodes) that DHCP should listen on. For the management node, this is normally the NICs that are connected to the service LAN and the NICs connected to the cluster management LAN:
chdef -t site clustersite dhcpinterfaces='mgmtnode|eth1,eth2,eth3,eth4'
Have xCAT configure the service network stanza for dhcpd and then start the daemon:
makedhcp -n
service dhcpd restart
Look at the DHCP configuration file on the xCAT management node to ensure that it contains only the networks you want:
cat /etc/dhcp/dhcpd.conf
If you need to make updates to the DHCP configuration file, you should stop the DHCP daemon, edit the DHCP configuration file, and then restart the DHCP daemon on your xCAT MN.
Before running any DFM hardware control commands in a large cluster, you should make sure the consoleondemand attribute in the site table is set to "yes". This is needed if there is a large number of LPARs and CECs. In the Power clusters that use DFM, the consoles are opened by fsp-api which sends command to the HWS daemon, which connects to the FSP. When set to 'no', all the consoles will be opened immediately (for logging), and it will affect the performance of the DFM hardware control commands. When set to 'yes', conserver connects to and logs the console output only when the user opens the console using the rcons command. The default is "no" on Linux, and "yes" on AIX.
chdef -t site clustersite consoleondemand=yes
After you change the change the consoleondemand=yes, you should run makeconservercf to take effects.
makeconservercf
For PowerLinux systems, the Machine Type/Model and Serial information was printed on the front panel of the Physical Server. The following steps can be used to make the hardware discovery process much easier.
mkdef cec01 nodetype=ppc mtm=8246-L1D serial=100A9DA groups=cec,all mgt=fsp hwtype=cec
mkdef cec01_fsp nodetype=ppc mtm=8246-L1D serial=100A9DA \
groups=fsp,all mgt=fsp parent=cec01 hwtype=fsp side=A-0 ip=10.0.0.21
makehosts
Note: The ip value for the FSP node is the permanent ip address that you'd like to assigned to it. It must be not belong to the DHCP dynamicrange you set in 'networks' table. makehosts will create the permanent ip address and nodename mapping.
When power is applied to the CECs, the FSPs power on. This should cause the FSPs to request and receive a dynamic IP address from DHCP. Information about the FSPs & CECs cannot be collected by the lsslp command below until this has taken place.
Run lsslp to discover the CECs/FSPs, and write additional attributes in the database.
lsslp -s CEC -w
For each FSP that was discovered on the network, the mac and parent attributes of the FSP node will be updated. You can confirm it by running:
lsdef -S cec1_fsp -i mac,parent
Review/verify all of the attributes of the CECs and FSPs:
lsdef cec
lsdef fsp -S # normally FSPs are hidden from output, so you need the -S flag
Verify that:
Configure DHCP with the static ip/mac pairs so that it will always give the FSPs their permanent IP address from now on:
makedhcp -n
makedhcp -a
Verify that the proper IP/MAC pairs were configured in dhcp:
cat /var/lib/dhcpd/dhcpd.leases # RHEL 6
The FSPs will renew their DHCP lease from the DHCP server about every five minutes. So after the DHCP daemon on the MN is configured (via makedhcp), the FSPs will get their permanent IP addresses sometime between 0 and 5 minutes later. The pping command can be used to see if the FSPs have obtained their new IP addresses. If an FSP has obtained its permanent IP address, the pping result will be: "<fsp ip>: ping".
pping fsp
For the FSPs that can't refresh their IP addresses, the --resetnet option of the rspconfig command can be used to force it. The rspconfig expects each FSP's otherinterfaces attribute to be set to the dynamic IP address that it currently has.
rspconfig cec02 --resetnet
To enable xCAT to connect to the FSPs, you must add the current passwords for the CEC/FSPs in the xCAT database. If the password for all of the CECs is the same, you can set the username/password in the passwd table:
chtab key=fsp,username=HMC passwd.password=xxx
chtab key=fsp,username=admin passwd.password=yyy
chtab key=fsp,username=general passwd.password=zzz
If the passwords for some of the CEC/FSPs are different, you can set the passwords for individual CEC/FSPs in the ppcdirect table:
chdef cec01 passwd.HMC=xxx passwd.admin=yyy passwd.general=zzz
Have xCAT's DFM daemon (called hw server) establish connections to all of the CEC/FSPs:
mkhwconn cec -t
If the FSP passwords are still the factory defaults, you must change them before running any other commands to them:
rspconfig cec general_passwd=,<newpd>
rspconfig cec admin_passwd=,<newpd>
rspconfig cec HMC_passwd=,<newpd>
Set the system name of the CEC to match the node name in the xCAT database. This is convenient because then the CEC names displayed in the ASM interface will match the CEC names in the xCAT database.
rspconfig cec 'sysname=*'
Verify the connections were made successfully:
lshwconn cec
cec01: sp=primary,ipadd=10.0.0.21,alt_ipadd=unavailable,state=LINE UP
...
Verify the hardware control setup is correct for the CECs:
rpower cec state
cec01: operating
...
The admin may need to upgrade the firmware of the CEC. This is accomplished by using the rflash xCAT command from the xCAT MN. The admin should download the supported GFW from the IBM Fix central website, and place it in a directory that is available to be read by the xCAT MN.
Use rinv command to get the current firmware levels of the CECs:
rinv cec firm
cec01: Release Level : 01AL770
cec01: Active Level : 048
cec01: Installed Level: 048
cec01: Accepted Level : 048
cec01: Release Level Primary: 01AL770
cec01: Level Primary : 048
cec01: Current Power on side Primary: temp
...
Make sure the pending-power-on side of the CEC's FSPs is set to temp. If not, set it to temp.
rspconfig cec pending_power_on_side
rspconfig cec pending_power_on_side=temp
Download the Microcode update package(end with rpm) and associated XML file from Fix Central.
The "Product Group" shall be "Power", "Product" shall be the Machine Type/Model of your power machine, and choose suitable entry in "Select from XXX" pulldown list. The files are similar to:
01SV810_108_081.rpm
01SV810_108_081.xml
Use the rflash command to update the firmware levels for the CECs. Then validate that the new firmware is loaded:
rflash cec -p <directory> --activate disruptive
rinv cec firm
The admin can now power on the CECs, and validate they come up to working state. You can monitor the power up of the CECs using the rpower and rvitals command. You are looking for the CECs to be "Operating" with a finished good state. If they are not in the "Operating" state, additional hardware debug will be necessary to understand the failure.
rpower cec on
rvitals cec lcds
rpower cec state
The rscan command reads the actual LPAR configuration in the CEC and creates node definitions in the xCAT database to reflect them. Before using rscan, you should put the cec in operating or standby state.
Run the rscan command against all of the CECs to create a stanza file of LPAR node definitions:
rscan cec -z > nodes.stanza
Edit the stanza file and give each LPAR definition the node name that you want it to have. Then create the definitions in the database:
cat nodes.stanza | mkdef -z
Use the lsdef command to display the node definitions to confirm they were created the way you want them.
In some situation especially the factory default CECs, there will only be one single LPAR in each CEC that has all of the resources assigned to it. The following steps can be used to simple you definition.
nodeadd cec[01-08]n01 groups=lpar,all
chdef -t group lpar parent='|(cec\d+).*|($1)|' id='|cec\d+n0?(\d+)|($1+0)|' hwtype=lpar nodetype=ppc,osi
rscan cec -w
Note: rscan cec -w will update node definitions if they are matching by attributes 'parent' and 'id', and write nodes that doesn't match.
In the end, you will get a node object cec01n01 for the default partition on CEC cec01. It will be similar to:
lsdef cec01n01
Object name: cec01n01
groups=lpar,all
hcp=cec01
hwtype=lpar
id=1
mgt=fsp
mtm=8246-L1D
nodetype=ppc,osi
parent=cec01
postbootscripts=otherpkgs
postscripts=syslog,remoteshell,syncfiles
serial=100A9DA
By default, in IBM Power CECs there will be a default full partition which has all of the physical resources assigned to it. The DB node object representing the default partition was created in the previous section Define the LPAR Nodes with rscan. You need to delete this default partition first before doing other partition operations.
For a new PowerLinux server, there is a default full partition with OS installed on it. The default partition object has been defined in last step, we suppose the object name is 'cec01n01'.
1. Modify the power off policy for all of the CECs to avoid the CEC shutdown after the default partition is powered off and removed.
rspconfig cec01 cec_off_policy=stayon
2. Power off the default partition since partitions can only be removed in power off ("Not Activated") state.
rpower cec01n01 off
3. Remove the partition from the CEC and release all the physical resource assigned to it.
rmvm cec01n01
Note: The sections list below don't need to be operated step by step. Each section can fulfill one function completely.
In order to customize the partitions more efficiently, the admin needs to know all the resources in the CEC:
[root@xcatmn ~]# lsvm cec
cec01: HYP Configurable Processors: 4, Avail Processors: 4.
HYP Configurable Memory:16.00 GB(256 regions).
HYP Available Memory: 15.38 GB(246 regions).
HYP Memory Region Size: 0.06 GB(64 MB).
cec01: All Physical I/O info:
65535,517,U78AB.001.WZSJW8D-P1-C6,0x21010205,0xffff(Empty Slot)
65535,516,U78AB.001.WZSJW8D-P1-C5,0x21010204,0xffff(Empty Slot)
65535,515,U78AB.001.WZSJW8D-P1-C4,0x21010203,0xffff(Empty Slot)
65535,514,U78AB.001.WZSJW8D-P1-C3,0x21010202,0x200(Ethernet Controller)
65535,513,U78AB.001.WZSJW8D-P1-C2,0x21010201,0x0(Non VGA device)
65535,13,U78AB.001.WZSJW8D-P1-C7,0x2104000d,0x200(Ethernet Controller)
65535,12,U78AB.001.WZSJW8D-P1-C18,0x2103000c,0xffff(Empty Slot)
65535,11,U78AB.001.WZSJW8D-P1-T5,0x2102000b,0x1003(Unknown Device)
65535,10,U78AB.001.WZSJW8D-P1-T9,0x2101000a,0x104(RAID Controller)
cec01: Huge Page Memory
Available huge page memory(in pages): 0
Configurable huge page memory(in pages): 0
Page Size(in GB): 16
Maximum huge page memory(in pages): 1
Requested huge page memory(in pages): 0
cec01: Barrier Synchronization Register(BSR)
Number of BSR arrays: 256
Bytes per BSR array: 4096
Available BSR array: 256
Note: The lines immedidiately following "All Physical I/O info" represent all the physical I/O resource information, and is in the format: "owner_lparid,slot_id,physical resource name,drc_index,slot_class_code(class discription)". The 'drc index' is short for Dynamic Resource Configuration Index, which uniquely indicates a physical I/O resource in a Power server.
This section describes how to do partition for powerLinux hardware with DFM. There are four kinds of partition are supported right now: 1. full partition 2. physical partition 3. VIOS partition 4. normal LPAR
Before creating partitions in a CEC, please make sure the partition definition had been created. If not exists, you can create the definition with the following command.
mkdef cec01n01 mgt=fsp cons=fsp nodetype=ppc,osi id=2 hcp=cec01 parent=cec01 hwtype=lpar groups=lpar,all
1 object definitions have been created or modified.
If you like to use the node definition updated with "rscan cec -w", you can modify the attribute of the node with the following command.
chdef cec01n01 mgt=fsp cons=fsp id=2 hcp=cec01 parent=cec01
1 object definitions have been created or modified.
Note: The 'hcp' and 'parent' attributes shall be set as the object name of the CEC that you'd like to create partition on. The customized partition must start with id '2', since rcons doesn't work for id '1' in some situations.
The node definition is similar to:
[root@xcatmn ~]# lsdef cec01n01
Object name: cec01n01
cons=fsp
groups=lpar,all
hcp=cec01
hwtype=lpar
id=2
mgt=fsp
nodetype=ppc,osi
parent=cec01
postbootscripts=otherpkgs
postscripts=syslog,remoteshell,syncfiles
[root@xcatmn ~]# chdef cec01n01 vmcpus=1/4/4 vmmemory=1/16/16 vmphyslots=0x2101000a,0x2104000d
1 object definitions have been created or modified.
[root@xcatmn ~]# mkvm cec01n01
cec01n01: Done
After the partition is created, check the partition resources:
[root@xcatmn ~]# lsvm cec01n01
cec01n01: Lpar Processor Info:
Curr Processor Min: 1.
Curr Processor Req: 4.
Curr Processor Max: 4.
cec01n01: Lpar Memory Info:
Curr Memory Min: 1.00 GB(16 regions).
Curr Memory Req: 15.25 GB(244 regions).
Curr Memory Max: 16.00 GB(256 regions).
cec01n01: 1,13,U78AB.001.WZSJW8D-P1-C7,0x2104000d,0x200(Ethernet Controller)
cec01n01: 1,10,U78AB.001.WZSJW8D-P1-T9,0x2101000a,0x104(RAID Controller)
cec01n01: 0/0/0
cec01n01: 0.
[root@xcatmn ~]# mkvm cec01n01 vmcpus=1/4/4 vmmemory=1/16/16 vmphyslots=0x2101000a,0x2104000d,0x21010202,0x21010201,0x2102000b vmothersetting=bsr:128
cec01n01: Done
Check the resources for the new partition:
[root@xcatmn ~]# lsvm cec01n01
cec01n01: Lpar Processor Info:
Curr Processor Min: 1.
Curr Processor Req: 4.
Curr Processor Max: 4.
cec01n01: Lpar Memory Info:
Curr Memory Min: 1.00 GB(16 regions).
Curr Memory Req: 15.25 GB(244 regions).
Curr Memory Max: 16.00 GB(256 regions).
cec01n01: 1,514,U78AB.001.WZSJW8D-P1-C3,0x21010202,0x200(Ethernet Controller)
cec01n01: 1,513,U78AB.001.WZSJW8D-P1-C2,0x21010201,0x0(Non VGA device)
cec01n01: 1,13,U78AB.001.WZSJW8D-P1-C7,0x2104000d,0x200(Ethernet Controller)
cec01n01: 1,11,U78AB.001.WZSJW8D-P1-T5,0x2102000b,0x1003(Unknown Device)
cec01n01: 1,10,U78AB.001.WZSJW8D-P1-T9,0x2101000a,0x104(RAID Controller)
cec01n01: 0/0/0
cec01n01: 128.
If you would like to modify the resources assigned of a partition, you can use chvm. Here is an example that modifies the cpu, memory, and physical slot info for the specified partition.
chvm cec01n01 vmcpus=1/2/4 vmmemory=1/8/16 add_physlots=0x21010203,0x2103000c vmothersetting=bsr:256
cec01n01: Success
cec01n01: Success
cec01n01: Success
cec01n01: Success
Checking the resources after modifying:
lsvm cec01n01
cec01n01: Lpar Processor Info:
Curr Processor Min: 1.
Curr Processor Req: 2.
Curr Processor Max: 4.
cec01n01: Lpar Memory Info:
Curr Memory Min: 1.00 GB(16 regions).
Curr Memory Req: 8.00 GB(128 regions).
Curr Memory Max: 16.00 GB(256 regions).
cec01n01: 1,515,U78AB.001.WZSJW8D-P1-C4,0x21010203,0xffff(Empty Slot)
cec01n01: 1,514,U78AB.001.WZSJW8D-P1-C3,0x21010202,0x200(Ethernet Controller)
cec01n01: 1,513,U78AB.001.WZSJW8D-P1-C2,0x21010201,0x0(Non VGA device)
cec01n01: 1,13,U78AB.001.WZSJW8D-P1-C7,0x2104000d,0x200(Ethernet Controller)
cec01n01: 1,12,U78AB.001.WZSJW8D-P1-C18,0x2103000c,0xffff(Empty Slot)
cec01n01: 1,11,U78AB.001.WZSJW8D-P1-T5,0x2102000b,0x1003(Unknown Device)
cec01n01: 1,10,U78AB.001.WZSJW8D-P1-T9,0x2101000a,0x104(RAID Controller)
cec01n01: 0/0/0
cec01n01: 256.
Note: the partition configuration parameters be modified using chvm will take effect in next boot.
Option 'full' for mkvm can be used to create a full partition.
mkvm cec01n01 --full
cec01n01: Done
Checking the resources:
lsvm cec01n01
cec01n01: Lpar Processor Info:
Curr Processor Min: 1.
Curr Processor Req: 4.
Curr Processor Max: 4.
cec01n01: Lpar Memory Info:
Curr Memory Min: 0.25 GB(4 regions).
Curr Memory Req: 15.25 GB(244 regions).
Curr Memory Max: 16.00 GB(256 regions).
cec01n01: 1,517,U78AB.001.WZSJW8D-P1-C6,0x21010205,0xffff(Empty Slot)
cec01n01: 1,516,U78AB.001.WZSJW8D-P1-C5,0x21010204,0xffff(Empty Slot)
cec01n01: 1,515,U78AB.001.WZSJW8D-P1-C4,0x21010203,0xffff(Empty Slot)
cec01n01: 1,514,U78AB.001.WZSJW8D-P1-C3,0x21010202,0x200(Ethernet Controller)
cec01n01: 1,513,U78AB.001.WZSJW8D-P1-C2,0x21010201,0x0(Non VGA device)
cec01n01: 1,13,U78AB.001.WZSJW8D-P1-C7,0x2104000d,0x200(Ethernet Controller)
cec01n01: 1,12,U78AB.001.WZSJW8D-P1-C18,0x2103000c,0xffff(Empty Slot)
cec01n01: 1,11,U78AB.001.WZSJW8D-P1-T5,0x2102000b,0x1003(Unknown Device)
cec01n01: 1,10,U78AB.001.WZSJW8D-P1-T9,0x2101000a,0x104(RAID Controller)
cec01n01: 0/0/0
cec01n01: 256.
1. To create the partition
Option 1: specify partition parameters with *def command
chdef <node> vmcpus=1/2/4 vmmemory=1/8/16 [vmphyslots=0x21010202,0x2104000d,0x2101000a] vmnics=vlan1,vlan2 vmstorage=5
Notes: vmnics=vlan1,vlan2 specify the vlan ID of virtual Ethernet adapter that will be created.
vmstorage=5 specify the virtual scsi server adapter will be created on VIOS partition.</node>
mkvm <node> --vios
Notes: --vios: used to specify that you are now creating a vios partition
If not specified vmphyslots, all the physical resource will be allocated to the VIOS partition.</node>
Option 2: specify partition parameters with *vm command
mkvm node --vios vmcpus=1/2/4 vmmemory=1/8/16 [vmphyslots=0x21010202,0x2104000d,0x2101000a]
vmnics=vlan1,vlan2 vmstorage=5
2. To change the partition configuration
chvm node --vios \
vmcpus=1/2/4 vmmemory=1/8/16 [add_physlots=0x21010202,0x2104000d,0x2101000a] add_vmnics=vlan3,vlan4 add_vmstorage=5
chvm node del_physlots=add_physlots=0x21010202,0x2104000d,0x2101000a
chvm node del_vadapter=slot_id
Notes: The new parameter for vmcpus, vmmemory and add_physlots will take affect for the next
power off of the node.
The virtual adapter created for add_vmnics, add_vmstorage will take affect immediately, but
you shall restart the node to apply those virtual adapter into OS.
For add_vmnics, the admin shall makesure no duplicated vlan ids used.
The slot_id for del_vadapter can only be deleted when the node is powered off or the virtual
adapter has not been applied to node OS yet.
1. To create the partition
chdef <node> vmcpus=1/2/4 vmmemory=1/8/16 [vmphyslots=0x21010202] vmnics=vlan1 \
vmstorage=viosnodename:slotid
Notes: vmnics=vlan1 specify the vlan ID of virtual Ethernet adapter that will be created.
vmstorage=viosnodename:slotid specify the vios node name and virtual scsi server adapter slot that the vscsi client adapter created on logical partition will connect to.
mkvm <node>
mkvm node vmcpus=1/2/4 vmmemory=1/8/16 [vmphyslots=0x21010202] vmnics=vlan1 vmstorage=viosnodename:slotid
2. To change the partition configuration
chvm node vmcpus=1/2/4 vmmemory=1/8/16 [add_physlots=0x21010202] add_vmnics=vlan1 add_vmstorage=viosnodename:slotid
chvm node del_physlots=0x21010202
chvm node del_vadapter=slot_id
The command rmvm can be used to remove all the resources assigned to the specified partition.
rmvm cec01n01
cec01n01: Done
There will be two iso file for a single vios OS, the admin must run copycds for the two iso file in order:
copycds -n vios2.2.2.2 -a ppc64 /iso/dvdimage.v1.iso
copycds -n vios2.2.2.2 -a ppc64 /iso/dvdimage.v2.iso
After copycds, an osimage object will be created like this:
lsdef -t osimage vios2.2.2.2_sysb
Object name: vios2.2.2.2_sysb
imagetype=NIM
osarch=ppc64
osdistroname=vios2.2.2.2
osname=AIX
provmethod=nimol
To configure ip address for vios partition, you can either though adding ip,hostname pair into /etc/hosts or through the following command:
chdef node ip=x.x.x.x
makehost node
chtab key=vios passwd.username=padmin passwd.password=cluster
makedns -n
makedns -a
makeconservercf node
getmacs node -D
chdef node netboot=nimol
nodeset node osimage= vios2.2.2.2_sysb
rbootseq node net
rpower node reset
Note: The installnic had been configured to be the physical
adapter of a SEA adapter if there were virtual Ethernet adapter created.
This section is about configuring virtual adapters.
lsvm vios1
...
vios1: 2,0,U8247.22L.10112CA-V2-C0,0x30000000,vSerial Server
vios1: 2,1,U8247.22L.10112CA-V2-C1,0x30000001,vSerial Server
vios1: 2,3,U8247.22L.10112CA-V2-C3,0x30000003,vEth (port_vlanid=1,mac_addr=423609722279)
vios1: 2,4,U8247.22L.10112CA-V2-C4,0x30000004,vEth (port_vlanid=2,mac_addr=421f0972227a)
vios1: 2,5,U8247.22L.10112CA-V2-C5,0x30000005,vSCSI Server
vios1: 2,6,U8247.22L.10112CA-V2-C6,0x30000006,vSCSI Server
...
xdsh vios1 -l padmin "ioscli lsdev -type adapter"
vios1: name status description
vios1: ent0 Defined N/A
vios1: ent1 Defined N/A
vios1: ent2 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent3 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent4 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent5 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent6 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent7 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent8 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent9 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent10 Available PCIe2 10GbE SFP+ SR 4-port Converged Network Adapter (df1020e214100f04)
vios1: ent11 Available PCIe2 10GbE SFP+ SR 4-port Converged Network Adapter (df1020e214100f04)
vios1: ent12 Available PCIe2 100/1000 Base-TX 4-port Converged Network Adapter (df1020e214103c04)
vios1: ent13 Available PCIe2 100/1000 Base-TX 4-port Converged Network Adapter (df1020e214103c04)
vios1: ent14 Available Virtual I/O Ethernet Adapter (l-lan)
vios1: ent15 Available Virtual I/O Ethernet Adapter (l-lan)
vios1: vhost0 Available Virtual SCSI Server Adapter
vios1: vhost1 Available Virtual SCSI Server Adapter
vios1: vsa0 Available LPAR Virtual Serial Adapter
In order to match the virtual device such as ent14/ent15 with the virtual ethernet adapter created with *vm, you need to first list the vpd information for the device, then match the "Hardware Location Code" with the slot information list in 'lsvm'.
xdsh vios1 -l padmin "ioscli lsdev -dev ent14 -vpd"
vios1: ent14 U8247.22L.10112CA-V2-C3-T1 Virtual I/O Ethernet Adapter (l-lan)
vios1:
vios1: Network Address.............423609722279
vios1: Displayable Message.........Virtual I/O Ethernet Adapter (l-lan)
vios1: Hardware Location Code......U8247.22L.10112CA-V2-C3-T1
vios1:
vios1: PLATFORM SPECIFIC
vios1:
vios1: Name: l-lan
vios1: Node: l-lan@30000003
vios1: Device Type: network
vios1: Physical Location: U8247.22L.10112CA-V2-C3-T1
You can get "vios1: 2,3,U8247.22L.10112CA-V2-C3,0x30000003,vEth (port_vlanid=1,mac_addr=423609722279)" contain the same Location code "U8247.22L.10112CA-V2-C3" with ent14, so the virtual slot num for ent14 is '3'. For more information about the meaning of lsvm output, pls reference manpage of lsvm.
xdsh vios1 -l padmin "ioscli mkvdev -sea ent2 -vadapter ent14 -default ent14 -defaultid 1"
vios1: ent16 Available
vios1: en16
vios1: et16
xdsh vios1 -l padmin "ioscli mktcpip -hostname vios1 -inetaddr 192.168.100.1 -interface en16 \
-netmask 255.255.255.0"
xdsh vios1 -l padmin "ioscli lsdev -type adapter"
vios1: name status description
vios1: ent0 Defined N/A
vios1: ent1 Defined N/A
vios1: ent2 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent3 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent4 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent5 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent6 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent7 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent8 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent9 Available 4-Port Gigabit Ethernet PCI-Express Adapter (e414571614102004)
vios1: ent10 Available PCIe2 10GbE SFP+ SR 4-port Converged Network Adapter (df1020e214100f04)
vios1: ent11 Available PCIe2 10GbE SFP+ SR 4-port Converged Network Adapter (df1020e214100f04)
vios1: ent12 Available PCIe2 100/1000 Base-TX 4-port Converged Network Adapter (df1020e214103c04)
vios1: ent13 Available PCIe2 100/1000 Base-TX 4-port Converged Network Adapter (df1020e214103c04)
vios1: ent14 Available Virtual I/O Ethernet Adapter (l-lan)
vios1: ent15 Available Virtual I/O Ethernet Adapter (l-lan)
vios1: ent16 Available Shared Ethernet Adapter
xdsh vios1 -l padmin "ioscli lsdev -type adapter"
vios1: name status description
...
vios1: vhost0 Available Virtual SCSI Server Adapter
vios1: vhost1 Available Virtual SCSI Server Adapter
vios1: vsa0 Available LPAR Virtual Serial Adapter
You can get 2 vscsi server adapter vhost0, vhost1 here.
In order to match the virtual device such as vhost0/vhost1 with the virtual SCSI adapter created with *vm, you need to first list the vpd information for the device, then match the "Hardware Location Code" with the slot information list in 'lsvm'.
xdsh vios1 -l padmin "ioscli lsdev -dev vhost0 -vpd"
vios1: vhost0 U8247.22L.10112CA-V2-C5 Virtual SCSI Server Adapter
vios1:
vios1: Hardware Location Code......U8247.22L.10112CA-V2-C5
vios1:
vios1: PLATFORM SPECIFIC
vios1:
vios1: Name: v-scsi-host
vios1: Node: v-scsi-host@30000005
vios1: Physical Location: U8247.22L.10112CA-V2-C5
You can get "vios1: 2,5,U8247.22L.10112CA-V2-C5,0x30000005,vSCSI Server" contain the same Location code "U8247.22L.10112CA-V2-C5" with vhost0, so the virtual slot num for vhost0 is '5'. For more information about the meaning of lsvm output, pls reference manpage of lsvm.
xdsh vios1 -l padmin "ioscli lspv"
vios1: NAME PVID VG STATUS
vios1: hdisk0 0001592a32970e2c rootvg active
All the hard disk are assigned to Volume Group rootvg, so we create a logical volume on it
xdsh vios1 -l padmin "ioscli mklv -lv rootvg_20G rootvg 20G"
vios1: rootvg_20G
xdsh vios1 -l padmin "ioscli mkvdev -vdev rootvg_20G -vadapter vhost0"
vios1: vtscsi0 Available
xdsh vios1 -l padmin "ioscli lsmap -vadapter vhost0"
vios1: SVSA Physloc Client Partition ID
vios1: --------------- -------------------------------------------- ------------------
vios1: vhost0 U8247.22L.10112CA-V2-C5 0x00000000
vios1:
vios1: VTD vtscsi0
vios1: Status Available
vios1: LUN 0x8100000000000000
vios1: Backing device rootvg_20G
vios1: Physloc
vios1: Mirrored N/A
The following command can be used to set up the SSH key for VIOS partition.
DSH_REMOTE_PASSWORD=<xxxx> xdsh vios1 -K -l padmin --devicetype=vios
/usr/bin/ssh setup is complete.
return code = 0
xdsh vios1 -l padmin date
vios1: Tue May 27 01:51:46 CDT 2014
IBM Power Servers support the Energy management capabilities like to query and monitor the
and to set the
xCAT offers the command 'renergy' to manipulate the Energy related features for Power Server. Refer to the man page of renergy to get the detail of usage.
Wiki: Defining_cluster_nodes_on_System_P
Wiki: Linux_AIX_mixed_cluster_configuration
Wiki: Mixed_Cluster_Support
Wiki: XCAT_Documentation
Wiki: XCAT_pLinux_Clusters