Menu

#632 Registrar max_expires not working

1.10.x
open
modules (454)
5
2013-05-10
2013-03-15
Paul
No

Opensips 1.9.0 max_expires is not working when set in the module parameters for all UA's. To force the setting, the exported save function has to be used with parameters.

Secondly, compilation errors on fedora 13 using gcc 4.4.5 . Some were not present in compiling opensips 1.8.2.

Discussion

  • Paul

    Paul - 2013-03-15
     
  • Paul

    Paul - 2013-03-30

    Specifically, max_expires parameter has no effect on "CSIP Simple" android mobile app. Android application sets register timeout at 900 secs on request. However, using the registrar "save" command with options, forces the site setting.

     
  • Bogdan-Andrei Iancu

    • assigned_to: nobody --> bogdan_iancu
     
  • Bogdan-Andrei Iancu

    Hi Paul,

    So what you are saying is that using the max_expire as flag in save() works, but setting it as module param does not ?

    Regards,
    Bogdan

     
  • Paul

    Paul - 2013-04-02

    Hi Bogdan, To answer your question, yes. The module parameter works for the other UA's except "CSIP Simple" on android. On a previous occasion, the said mod param was also not forcing the setting for the Yealink hard phones, but it is now; not sure why the inconsistency.

    In all cases, the exported save function with arguments forces the max_expires for all UA's.

    Not critical, but reporting due to observation.

     

Log in to post a comment.